Information | Suggestions | Not your typical sterilizer | Manufacturer information | Cost / benefit ratio: |
|
![]() |
Statim 2000S 8 minute complete sterilization cycle Statim 5000S 11 minute complete sterilization cycle Think of how much time and money that'll save you |
|
|
|
|
Statim’s revolutionary technology allows you to sterilize up to 8x faster than a common ‘round chamber’ style autoclave. What’s the advantage? Statim’s incredible 6 minute cycle will allow you to sterilize instruments between procedures, or simply as you need them.Statim is also the most versatile autoclave available. Whether you choose to process wrapped or unwrapped instrument loads, Statim has an unprecedented, ultra fast cycle speed for each. However, perhaps the biggest advantage is Statim’s unique removable chamber design which allows for the aseptic transport of unwrapped instrument loads from the instrument reprocessing area directly to the procedure room - an industry first. This feature will allow you to take regular advantage of Statim’s fully validated unwrapped cycle. You will be able to maximize your efficiency as there’s less need to store large inventories of instruments or jewelry to get you through the day. Use fewer instruments more often. What are you waiting for? |
![]() Fully removable sterilization chamber STATIM’s unique, removable sterilization chamber is the only one of its kind providing aseptic instrument delivery immediately upon completion of a cycle. Simply remove the closed chamber and deliver instruments aseptically directly to the procedure area. Statim 2000 and cassette shown |
![]() Extremely gentle on instruments STATIM’s unique steam injection system forces residual air out of the chamber as steam is introduced for sterilization. The result is little to no corrosion over time, drastically increasing the life instruments Statim 5000 extra length cassette shown |
|
![]() Remarkable instrument turnover Because STATIM can run up to 8x faster than a traditional ‘round chamber’ autoclave it can process large volumes of instruments. Statim 5000S cassette with baskets shown |
|
|
STATIM 2OOOS CASSETTE AUTOCLAVE The eight-minute STATIM Cassette Autoclave. Through innovative technological advances, the STATIM Cassette Autoclave has set the worldwide standard against which all sterilizers are judged. This compact table-top unit is designed for the efficient, economical and rapid steam sterilization of medical/surgical instrumentation. The STATIM's uniquely designed cassette pressure chamber and controlled steam system result in a safe, easy-to-operate sterilization device that is not only kind to delicate instruments but will allow complete sterilization between each patient.
Autoclaves |
||||
|
STATIM Autoclaves Statim FAQ
|
SciCan Accessories![]() ![]() ![]() ![]() ![]() ![]() |
HYDRIM Instrument washers Powerful cleaning...the first step to effective sterilization Virtually eliminates hand scrubbing of instruments - HYDRIM Brochures - International information ![]() ![]() ![]() Why Use An Automated Washer? The advantages of automated washing systems over traditional manual cleaning are recognized by the CDC and independent research and testing organizations. If it's not clean, it can't be sterilized. SciCan offers the tabletop HYDRIM C51w instrument washer and the newly redesigned floor model HYDRIM L110w to meet the needs of your practice. See video below for more detail.
|
||
|
A fast and effective way to
make your own distilled water
A new wave breakthrough provides 99% pure, fresh water. Protect your patients and your Statim Cassette Autoclave® by using only pure, fresh water in your practice. SciCan's AQUASTAT distiller allows you to forget about buying expensive bottled water or risking damage to your equipment from less than pure distilled water. A patented distillation technology kills harmful bacteria and viruses by flash vaporizing water and then reconstituting it through condensation. The result is water that's 99% pure. So pure, you could even drink it! |
||||
Financing available! |
||||
|
An all disposable procedure saves body artists hundreds of hours of labor It is not necessary to have an additional autoclave if you have a STATIM. The wrapped cycle will out perform any type N gravity displacement steam sterilizer, and type B vacuum sterilizers. [The STATIM S series are available in European Union countries, and have established a new higher standard for sterilization. They are distinguished from their STATIM counterparts by a 90 second longer conditioning phase and an 18 minute wrapped cycle to accommodate EN13060]
|
|
| Cost / benefit ratio for body artists: | ||
Gravity Displacement Autoclave
|
STATIMSterile gloves - .18 Cost for 100 piercings: $18 |
Results per 100 Procedures
|
Time to prep 100 piercings: 3 Hrs(Includes needle, jewelry, pre-packs) |
Time to prep 100 piercings:
|
Results per Year (3000 Procedures)
|
Time to sterilize 100 set ups: 15 Hrs(10 set ups per cycle) |
Time to sterilize 100 set ups:
|
Results per Year (5000 Procedures)
|
Total hours labor: 18 |
Total hours labor: 11 |
![]() |
THE STATIM CASSETTE AUTOCLAVE STERILIZER SYSTEM |
|
The STATIM is not your typical sterilizer |
* Here are some reasons why: |
*FASTStatIM 2000 delivers sterile instruments in 6 ½ minutes ready for use using fresh water each cycle, drying instruments without exposing them to external air. |
*SAFEBody Piercing, Tattooing, Dental, Laparoscopy, Arthroscopy Cystoscopy & ENT procedures, protects expensive instruments and handpieces. The patented air removal system ensures effective sterilization with no oxidation to your instruments and removes the air even in hollow instruments. No harmful chemicals that may possibly risk staff and patient to exposure. |
*SAVE $StatIM cycle cost is approximately .04 cents versus the much higher cost of packaging and storage. It saves time and money and allows for greater flexibility in your practice by avoiding pre-packaging equipment and jewelry. |
*ASEPTIC TRANSFERStatIM cassette offers the solution to the concern of aseptic transfer of sterilized items from the sterilizer to the point of use. The instruments are not exposed to external air as with open trays, thus allowing the operator to transport through non-sterile areas with no concern of breaking sterility. |
The STATIM is the easiest, most cost effective and convenient sterilizing system available! |
|
overview
Today's challenge of infection control and the demands of modern patient
treatment are met with SciCan's state of the art sterilization technology. In
1989, SciCan introduced the first STATIM Cassette Autoclave® to the
marketplace. Today, dental and medical practitioners in over 60 countries world
wide rely on STATIM to protect their patients and staff from infection from
contaminated instruments.
Although STATIM was originally developed for use in Dental applications, STATIM delivers complete sterilization solutions for Endoscopy, Gynecology, Ophthalmology and other medical areas.
Since SciCan began manufacturing, its autoclaves have won several design and product awards in Canada and Europe. As sales continue to grow, several versions of innovative SciCan autoclaves have been introduced to thousands of dental and medical offices and hospitals throughout the world.
After a cycle is chosen and the start button is pressed, the steam generator heats to the optimum temperature. A defined volume of distilled water is then pumped and converted to steam. The wall of steam is injected into the pressure chamber and cassette, which is loaded with contaminated instruments. Air is purged as the steam courses through the cassette and is continuously expelled into a condenser flask.
After the sterilizing cycle is completed, a small air compressor switches on, drying and cooling the instruments rapidly (STATIM 2000 and 5000 only). The STATIM system completely sterilizes instruments within international standards and it only uses clean distilled water, preventing the build up of rust and other contaminants.